Galaxy Tab S10 FE Wi-Fi Side Button and Fingerprint Sensor Replacement

For Samsung Galaxy Tab S10 FE Wi-Fi SM-X520 only. See pp. 152–163 and 125–140 of Samsung’s English repair guide, Rev. 1.1 for the part, connector and tool diagrams. Do not infer fit for other regional variants.

Back up the tablet, fully discharge the battery, unplug and turn it off. Wear eye protection and use ESD-safe tools. Stop for a swollen, hot, damaged or leaking battery. Never microwave the tablet. Keep screws mapped. Replace the display perimeter adhesive and connector tapes whenever you remove the display.

Remove

Open through the display, not the rear shell. Remove the microSD tray and follow the display and bracket instructions on pp. 56–89, then isolate the battery at the mainboard before the component work. Disconnect the white coax and clear it from the rear camera. Separate the five mainboard connections and remove the screen flex as shown. Remove one screw each at the mainboard and VT board, lift them at the indicated points and retain both boards. Skip the four cellular-only coax lines. Remove the two metal-retainer screws, lift off the retainer and free the fingerprint flex and water-resistant tape at the plastic bracket. Do not pry the sensor out from the outside.

Fit the replacement

Fit the module and plastic carrier using the correct liners, then fit new water-resistant tape. Reinstall the metal retainer with the two 3520 screws. Restore the mainboard and VT board with one 3521 screw each, reconnect the five illustrated connectors and restore the white coax. Reconnect the battery after the other electrical work, install the bracket with all 18 screws marked 3570, and reseal the display with fresh perimeter and connector tapes.

Check the repair

Test power and wake control, fingerprint recognition and the display. Do not assume an optical fingerprint calibration applies to a side reader.

Run relevant Samsung Members diagnostics and consult the model-specific Self Repair Assistant instructions. Stop if tests or calibrations fail. Opening the tablet does not guarantee restoration of its original water resistance.